MagPro Conventional Zone Module with Isolator - EN54-18

£9699
The RRP is the manufacturer's recommended retail price of the item.
Limited Stock
We are an Independent UK Company
Price match. Found it cheaper? Contact us
Trade Discount Available
Description

The MagPro Conventional Zone Module is a loop-powered interface unit that connects conventional fire detection devices to addressable fire alarm systems. The module monitors a single conventional zone of up to 32 detectors or call points, translating their analogue alarm signals into addressable data that the main fire panel can read and locate. A built-in isolator protects the addressable loop from short-circuit faults originating in the conventional zone.

Designed for retrofit installations where existing conventional beam detectors, heat detectors or manual call points need integrating into a newer addressable panel, the module removes the need to replace functional conventional equipment during a system upgrade. It also suits new installations where specific conventional devices (particularly long-range beam detectors in warehouses or atriums) offer better coverage than addressable equivalents. The module draws power directly from the addressable loop, requiring no separate supply.

The green PCB visible in the housing handles zone monitoring, fault detection and communication with the addressable loop controller. Terminal blocks on the left and bottom edges accept connections for the conventional zone wiring and the addressable loop in/out. The grey ABS enclosure measures approximately 180mm x 130mm x 50mm and is designed for wall mounting in plant rooms, risers or ceiling voids where ambient temperatures remain within the module's operating range.

EN54-18 certification confirms compliance with the European standard for input/output devices used in fire detection and alarm systems. The isolator function ensures that a short circuit on the conventional zone side does not bring down the entire addressable loop, maintaining system integrity during fault conditions.

Specification
Product Net Weight 0.32 kg
Product Gross Weight 0.33 kg
Frequently Asked

What is the maximum number of conventional detectors per zone?

The module supports up to 32 conventional fire detectors or manual call points on a single monitored zone. This limit is determined by the current-drawing capacity of the zone circuit and the module's ability to reliably detect alarm conditions across that number of devices.

Does the module require a separate power supply?

No. The module is loop-powered, drawing all operating power from the addressable fire alarm loop it connects to. No external DC supply or mains connection is needed.

What does the built-in isolator do?

The isolator protects the addressable loop from short-circuit faults that occur on the conventional zone side. If the conventional wiring or a connected device short-circuits, the isolator disconnects that fault from the addressable loop, preventing the entire loop from going offline.

What types of conventional devices can be connected?

The module accepts any conventional fire detection device that operates on a monitored two-wire zone circuit, including heat detectors, smoke detectors, beam detectors and manual call points. Beam detectors in large open spaces are a common application where conventional devices are still preferred.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.

See it lit, in person

Lighting looks different in a real room. Come and see our range at our showrooms in Birmingham, Hong Kong and Dubai, or talk to our design team wherever you are.

Niori lighting showroom trailer video with closeups of alabaster lighting

Why Niori

Over 20 years lighting homes worldwide

We are a specialist lighting and mirror retailer with showrooms in Birmingham, Hong Kong and Dubai, shipping to customers around the world. Our own design team is here to help, from first idea to final fitting.

Genuine products

An authorised stockist

Every product arrives brand new with the full manufacturer warranty. Found it cheaper elsewhere? Ask us about a price match.

Ordering with us

Free delivery over £99

Free delivery on orders over £99, in the UK and worldwide. Easy returns within 14 days, subject to our returns policy. Full manufacturer warranty included.

Design help

Not sure what you need?

Our design team can help you plan your lighting, share photos and videos of stock, and send samples worldwide. Book a showroom visit in Birmingham, Hong Kong or Dubai, or ask about our lighting design service.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The MagPro Conventional Zone Module is a loop-powered interface unit that connects conventional fire detection devices to addressable fire alarm systems. The module monitors a single conventional zone of up to 32 detectors or call points, translating their analogue alarm signals into addressable data that the main fire panel can read and locate. A built-in isolator protects the addressable loop from short-circuit faults originating in the conventional zone.

Designed for retrofit installations where existing conventional beam detectors, heat detectors or manual call points need integrating into a newer addressable panel, the module removes the need to replace functional conventional equipment during a system upgrade. It also suits new installations where specific conventional devices (particularly long-range beam detectors in warehouses or atriums) offer better coverage than addressable equivalents. The module draws power directly from the addressable loop, requiring no separate supply.

The green PCB visible in the housing handles zone monitoring, fault detection and communication with the addressable loop controller. Terminal blocks on the left and bottom edges accept connections for the conventional zone wiring and the addressable loop in/out. The grey ABS enclosure measures approximately 180mm x 130mm x 50mm and is designed for wall mounting in plant rooms, risers or ceiling voids where ambient temperatures remain within the module's operating range.

EN54-18 certification confirms compliance with the European standard for input/output devices used in fire detection and alarm systems. The isolator function ensures that a short circuit on the conventional zone side does not bring down the entire addressable loop, maintaining system integrity during fault conditions.

Specification
Product Net Weight 0.32 kg
Product Gross Weight 0.33 kg
Frequently Asked

What is the maximum number of conventional detectors per zone?

The module supports up to 32 conventional fire detectors or manual call points on a single monitored zone. This limit is determined by the current-drawing capacity of the zone circuit and the module's ability to reliably detect alarm conditions across that number of devices.

Does the module require a separate power supply?

No. The module is loop-powered, drawing all operating power from the addressable fire alarm loop it connects to. No external DC supply or mains connection is needed.

What does the built-in isolator do?

The isolator protects the addressable loop from short-circuit faults that occur on the conventional zone side. If the conventional wiring or a connected device short-circuits, the isolator disconnects that fault from the addressable loop, preventing the entire loop from going offline.

What types of conventional devices can be connected?

The module accepts any conventional fire detection device that operates on a monitored two-wire zone circuit, including heat detectors, smoke detectors, beam detectors and manual call points. Beam detectors in large open spaces are a common application where conventional devices are still preferred.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.