The ESP MagDuo is a configurable input/output relay module for fire alarm control panels, designed to interface between the panel and external systems or devices. The module can be configured as either an input to receive signals from external equipment (such as sprinkler flow switches, gas suppression systems, or third-party detectors) or as an output to trigger external devices (such as door releases, damper controls, or building management systems).

Installed within fire alarm zones as part of a two-wire addressable system, the MagDuo allows fire alarm panels to communicate with equipment outside the core detection network. The built-in End of Line (EOL) function monitors circuit integrity, providing fault indication if the supervised circuit becomes open or short-circuited. Two LED indicators on the faceplate show EOL/input status and output status, allowing engineers to verify module operation during commissioning and testing.

The module mounts on a standard electrical back box and is approved to EN54-18:2005 for use in European fire detection systems. The white surround and black faceplate with printed status labels give clear visual feedback during service and maintenance. Dimensions of 150mm × 150mm × 80mm accommodate the relay mechanism and terminal connections behind the cover plate.

Specification
Product Net Weight 0.15 kg
Product Gross Weight 0.2 kg
Dimensions 150 x 150 x 80 mm
Frequently Asked

Can the MagDuo be used as both input and output simultaneously?

No. The module is configured as either an input or an output during installation, not both at once. If both input and output functions are needed in the same zone, two separate MagDuo modules are required.

What does the End of Line function monitor?

The built-in EOL monitors the supervised circuit connected to the module. If the circuit becomes open or short-circuited, the module signals a fault condition to the fire alarm panel, allowing the fault to be identified during routine testing or system monitoring.

What external devices can be controlled in output mode?

Common applications include magnetic door holders, fire damper actuators, building management system interfaces, smoke extract fans, and suppression system release circuits. The relay contact rating determines the maximum load — consult the specification sheet for exact relay ratings.

Is the module compatible with all fire alarm panels?

The MagDuo is designed for use with ESP two-wire addressable fire alarm control panels. Compatibility with other manufacturers' panels depends on their support for EN54-18 compliant modules. Check with your panel manufacturer or consult the MagDuo installation manual before specifying.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.

See it lit, in person

Lighting looks different in a real room. Come and see our range at our showrooms in Birmingham, Hong Kong and Dubai, or talk to our design team wherever you are.

Niori lighting showroom trailer video with closeups of alabaster lighting

Why Niori

Over 20 years lighting homes worldwide

We are a specialist lighting and mirror retailer with showrooms in Birmingham, Hong Kong and Dubai, shipping to customers around the world. Our own design team is here to help, from first idea to final fitting.

Genuine products

An authorised stockist

Every product arrives brand new with the full manufacturer warranty. Found it cheaper elsewhere? Ask us about a price match.

Ordering with us

Free delivery over £99

Free delivery on orders over £99, in the UK and worldwide. Easy returns within 14 days, subject to our returns policy. Full manufacturer warranty included.

Design help

Not sure what you need?

Our design team can help you plan your lighting, share photos and videos of stock, and send samples worldwide. Book a showroom visit in Birmingham, Hong Kong or Dubai, or ask about our lighting design service.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The ESP MagDuo is a configurable input/output relay module for fire alarm control panels, designed to interface between the panel and external systems or devices. The module can be configured as either an input to receive signals from external equipment (such as sprinkler flow switches, gas suppression systems, or third-party detectors) or as an output to trigger external devices (such as door releases, damper controls, or building management systems).

Installed within fire alarm zones as part of a two-wire addressable system, the MagDuo allows fire alarm panels to communicate with equipment outside the core detection network. The built-in End of Line (EOL) function monitors circuit integrity, providing fault indication if the supervised circuit becomes open or short-circuited. Two LED indicators on the faceplate show EOL/input status and output status, allowing engineers to verify module operation during commissioning and testing.

The module mounts on a standard electrical back box and is approved to EN54-18:2005 for use in European fire detection systems. The white surround and black faceplate with printed status labels give clear visual feedback during service and maintenance. Dimensions of 150mm × 150mm × 80mm accommodate the relay mechanism and terminal connections behind the cover plate.

Specification
Product Net Weight 0.15 kg
Product Gross Weight 0.2 kg
Dimensions 150 x 150 x 80 mm
Frequently Asked

Can the MagDuo be used as both input and output simultaneously?

No. The module is configured as either an input or an output during installation, not both at once. If both input and output functions are needed in the same zone, two separate MagDuo modules are required.

What does the End of Line function monitor?

The built-in EOL monitors the supervised circuit connected to the module. If the circuit becomes open or short-circuited, the module signals a fault condition to the fire alarm panel, allowing the fault to be identified during routine testing or system monitoring.

What external devices can be controlled in output mode?

Common applications include magnetic door holders, fire damper actuators, building management system interfaces, smoke extract fans, and suppression system release circuits. The relay contact rating determines the maximum load — consult the specification sheet for exact relay ratings.

Is the module compatible with all fire alarm panels?

The MagDuo is designed for use with ESP two-wire addressable fire alarm control panels. Compatibility with other manufacturers' panels depends on their support for EN54-18 compliant modules. Check with your panel manufacturer or consult the MagDuo installation manual before specifying.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.