Description
This accessible toilet alarm reset module provides remote control and status indication for ESP disabled toilet alarm systems, specifically the UDTAKITSS. The 92mm square stainless steel faceplate mounts a red triangular LED indicator, audible alert sounder, and a triangular reset button marked 'RESET' in red lettering. When the toilet alarm is activated by a pull cord inside the accessible WC, this module illuminates the red LED and sounds an audible alert outside the room, allowing staff or responders to identify which facility requires assistance.
Designed for installation outside accessible toilet doors in commercial, retail, hospitality and public building environments, the module sits at waist or chest height on the corridor wall where it's visible to passing staff or security. The reset function allows staff to silence the alarm and turn off the LED after responding to the call, without needing to enter the toilet cubicle. The stainless steel finish matches commercial washroom hardware and resists fingerprints and surface marks in high-traffic environments.
The module wires back to the main alarm control panel inside the accessible toilet using low-voltage cabling, typically run through ceiling voids or surface-mounted trunking. The 48mm depth allows installation in standard 25mm back boxes with the front plate projecting approximately 23mm from the wall surface. The triangular reset button requires a deliberate press to activate, preventing accidental resets while remaining accessible to users with limited dexterity.
Specification
| Materials |
Stainless Steel (Grade 304) |
| Mounting |
Surface or Flush (Surface Back Box Not Included) |
| Operating Voltage |
12V DC |
| Power Consumption |
0.9W |
| Maximum Cable Size |
1.5mm² |
| Indication |
LED illuminates in red when in alarm state |
| Dimensions |
87 x 87 x 41mm |
| Product Net Weight |
0.14KG |
| Product Gross Weight |
0.17KG |
Downloads
Product Specification Sheet
Product Manual
Frequently Asked
What alarm system is this compatible with?
This reset module is designed for use with the ESP UDTAKITSS accessible toilet alarm kit. It will not function as a standalone unit and requires the main control panel inside the toilet cubicle to operate.
Where should the module be installed?
The module should be mounted outside the accessible toilet door at waist or chest height, typically 1000-1200mm from finished floor level, where it's visible to staff or security personnel passing in the corridor.
What back box depth is required?
The module requires a standard 25mm minimum back box depth. The total projection from the wall once fitted is approximately 48mm including the faceplate.
Does the reset button silence the alarm inside the toilet?
Yes. Pressing the triangular reset button silences both the audible alert on the remote module and the alarm sounder inside the toilet cubicle, and extinguishes the red LED indicator.