Free Delivery on all orders over £99*

13A Switched Fused Spur With Neon & Flex Outlet - Brushed Chrome Square Edge

£1099
The RRP is the manufacturer's recommended retail price of the item.
120 In Stock - Ready to Ship
We are an Independent UK Company
Price match. Found it cheaper? Contact us
Trade Discount Available
Description

The Knightsbridge 13A switched fused spur combines a double-pole isolating switch, a 13A fuse carrier, a neon indicator and a flex outlet behind a brushed chrome square edge faceplate. The unit provides switched isolation for fixed appliances such as boilers, kitchen extractors, water heaters and ventilation fans, with the flex outlet allowing hard-wired appliance cables to enter through the faceplate rather than requiring a separate grommet.

Designed for residential, hospitality and commercial installation, the fused spur fits a standard 25mm minimum back box depth and uses screw terminals rated for both mains supply and load connections. The neon indicator glows red when the switch is on, providing visual confirmation of live supply to the connected appliance without needing to check the appliance itself. The double-pole switching isolates both live and neutral lines when off, giving full isolation for maintenance.

The brushed chrome finish on premium-grade steel provides a directional grain texture that softens reflections and pairs cleanly with modern, industrial and transitional interiors. The square edge profile sits flush against flat wall surfaces with a built-in gasket sealing against the back box to prevent draughts and dust ingress. The unit carries BS 1363-4 certification and an IP20 rating for standard indoor dry locations, with a 25-year warranty covering manufacturing defects.

Specification
Height 89 mm
Width 89 mm
Projection 10.5 mm
Min. Mounting Box Depth 25mm
Construction Premium grade steel
Finish Brushed Chrome
IP Rating IP20
Primary Voltage 230V 50Hz
Earth Terminal Yes
Neon Indicator Yes
Terminal Screw
Warranty 25
Frequently Asked

What appliances is a fused spur used for?

Fused spurs provide permanent switched isolation for fixed appliances such as boilers, kitchen extractors, water heaters, ventilation fans, wall-mounted air conditioning units and electric towel rails. The 13A fuse protects the appliance circuit independently of the ring main.

What back box depth is required?

A 25mm minimum back box depth is needed for safe installation. The faceplate adds 10.5mm of projection from the wall once fitted.

What does the flex outlet do?

The flex outlet is a knockout aperture in the faceplate that allows the appliance cable to enter through the unit rather than requiring a separate cable grommet or surface-mounted trunking. This gives a cleaner finish when hard-wiring appliances.

Can the neon indicator be disabled?

The neon is wired directly into the switch mechanism to indicate live supply. It cannot be disabled without modifying the unit, which would void the warranty and BS 1363-4 certification.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.

See it lit, in person

Lighting looks different in a real room. Come and see our range at our showrooms in Birmingham, Hong Kong and Dubai, or talk to our design team wherever you are.

Niori lighting showroom trailer video with closeups of alabaster lighting

Why Niori

Over 20 years lighting homes worldwide

We are a specialist lighting and mirror retailer with showrooms in Birmingham, Hong Kong and Dubai, shipping to customers around the world. Our own design team is here to help, from first idea to final fitting.

Genuine products

An authorised stockist

Every product arrives brand new with the full manufacturer warranty. Found it cheaper elsewhere? Ask us about a price match.

Installation

Fits standard UK back boxes

Designed to fit standard UK back boxes for a straightforward swap of your existing fittings.

Ordering with us

Free delivery over £99

Free delivery on orders over £99, in the UK and worldwide. Easy returns within 14 days, subject to our returns policy. Full manufacturer warranty included.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The Knightsbridge 13A switched fused spur combines a double-pole isolating switch, a 13A fuse carrier, a neon indicator and a flex outlet behind a brushed chrome square edge faceplate. The unit provides switched isolation for fixed appliances such as boilers, kitchen extractors, water heaters and ventilation fans, with the flex outlet allowing hard-wired appliance cables to enter through the faceplate rather than requiring a separate grommet.

Designed for residential, hospitality and commercial installation, the fused spur fits a standard 25mm minimum back box depth and uses screw terminals rated for both mains supply and load connections. The neon indicator glows red when the switch is on, providing visual confirmation of live supply to the connected appliance without needing to check the appliance itself. The double-pole switching isolates both live and neutral lines when off, giving full isolation for maintenance.

The brushed chrome finish on premium-grade steel provides a directional grain texture that softens reflections and pairs cleanly with modern, industrial and transitional interiors. The square edge profile sits flush against flat wall surfaces with a built-in gasket sealing against the back box to prevent draughts and dust ingress. The unit carries BS 1363-4 certification and an IP20 rating for standard indoor dry locations, with a 25-year warranty covering manufacturing defects.

Specification
Height 89 mm
Width 89 mm
Projection 10.5 mm
Min. Mounting Box Depth 25mm
Construction Premium grade steel
Finish Brushed Chrome
IP Rating IP20
Primary Voltage 230V 50Hz
Earth Terminal Yes
Neon Indicator Yes
Terminal Screw
Warranty 25
Frequently Asked

What appliances is a fused spur used for?

Fused spurs provide permanent switched isolation for fixed appliances such as boilers, kitchen extractors, water heaters, ventilation fans, wall-mounted air conditioning units and electric towel rails. The 13A fuse protects the appliance circuit independently of the ring main.

What back box depth is required?

A 25mm minimum back box depth is needed for safe installation. The faceplate adds 10.5mm of projection from the wall once fitted.

What does the flex outlet do?

The flex outlet is a knockout aperture in the faceplate that allows the appliance cable to enter through the unit rather than requiring a separate cable grommet or surface-mounted trunking. This gives a cleaner finish when hard-wiring appliances.

Can the neon indicator be disabled?

The neon is wired directly into the switch mechanism to indicate live supply. It cannot be disabled without modifying the unit, which would void the warranty and BS 1363-4 certification.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.