Free Delivery on all orders over £99*

13A RCD Fused Spur Type A 30mA - Anthracite Part M Compliant

£3099
The RRP is the manufacturer's recommended retail price of the item.
120 In Stock - Ready to Ship
We are an Independent UK Company
Price match. Found it cheaper? Contact us
Trade Discount Available
Description

The Knightsbridge 13A RCD fused spur combines a Type A residual current device with a switched fused connection unit behind an anthracite curved edge faceplate. The 30mA RCD monitors for earth leakage and trips within 40ms when it detects an imbalance, isolating the circuit to prevent electric shock. Type A protection covers both AC residual currents and pulsating DC currents up to 6mA, making it suitable for circuits feeding IT equipment, variable-speed motors, and appliances with electronic controls.

Part M compliance means the unit meets Building Regulation requirements for accessible dwellings and communal areas. The anthracite faceplate carries a Light Reflectance Value (LRV) of 8.9, providing sufficient visual contrast against typical wall finishes (most white walls measure LRV 75-85) to help visually impaired users locate the switch. The passive latching RCD resets automatically after a power cut, so circuits feeding essential appliances like fridges and freezers are not left isolated without manual intervention.

The unit requires a 35mm minimum back box depth and uses captive screw terminals that remain attached to the back plate during installation, reducing the risk of lost fixings. The thermoset resin construction is third-party tested to ISO 22196:2011 for anti-microbial properties, inhibiting bacterial growth on the surface in kitchens, bathrooms and clinical environments. The fused spur section accepts a standard 13A BS 1362 cartridge fuse (not included), allowing the load to be appropriately protected downstream of the RCD.

Specification
Height 86 mm
Width 86 mm
Projection 12 mm
Min. Mounting Box Depth 35mm
Construction Thermoset resin
Finish Anthracite
IP Rating IP20
Primary Voltage 230V 50Hz
Earth Terminal Yes
Terminal Captive
RCD functionality 30mA Type-A latching
Anti-Microbial Properties 3rd Party Tested to ISO 22196:2011
Warranty 2
Frequently Asked

What does Type A RCD protection cover?

Type A RCDs detect both standard AC earth leakage and pulsating DC residual currents up to 6mA. This makes them suitable for circuits feeding modern appliances with electronic controls, variable-speed drives, IT equipment, and LED lighting — all of which can introduce DC components that a standard AC-only RCD may not detect reliably.

Does the RCD need resetting after a power cut?

No. The passive latching design resets automatically when mains power is restored, so circuits feeding fridges, freezers and other essential appliances remain operational without manual intervention after an outage.

What fuse does the spur section take?

The fused spur accepts a standard 13A BS 1362 cartridge fuse (the same type used in UK plugs). The fuse is not included and must be selected based on the downstream load — typically 3A for lighting circuits, 5A for low-power appliances, or 13A for higher loads up to the maximum rating.

Is it suitable for bathroom installation?

The unit carries an IP20 rating, which is appropriate for indoor dry areas and zones outside the bathroom's direct spray/splash areas. It cannot be installed within zones 0, 1 or 2 of a bathroom as defined by BS 7671 wiring regulations. Consult a qualified electrician to confirm placement.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.

See it lit, in person

Lighting looks different in a real room. Come and see our range at our showrooms in Birmingham, Hong Kong and Dubai, or talk to our design team wherever you are.

Niori lighting showroom trailer video with closeups of alabaster lighting

Why Niori

Over 20 years lighting homes worldwide

We are a specialist lighting and mirror retailer with showrooms in Birmingham, Hong Kong and Dubai, shipping to customers around the world. Our own design team is here to help, from first idea to final fitting.

Genuine products

An authorised stockist

Every product arrives brand new with the full manufacturer warranty. Found it cheaper elsewhere? Ask us about a price match.

Installation

Fits standard UK back boxes

Designed to fit standard UK back boxes for a straightforward swap of your existing fittings.

Ordering with us

Free delivery over £99

Free delivery on orders over £99, in the UK and worldwide. Easy returns within 14 days, subject to our returns policy. Full manufacturer warranty included.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The Knightsbridge 13A RCD fused spur combines a Type A residual current device with a switched fused connection unit behind an anthracite curved edge faceplate. The 30mA RCD monitors for earth leakage and trips within 40ms when it detects an imbalance, isolating the circuit to prevent electric shock. Type A protection covers both AC residual currents and pulsating DC currents up to 6mA, making it suitable for circuits feeding IT equipment, variable-speed motors, and appliances with electronic controls.

Part M compliance means the unit meets Building Regulation requirements for accessible dwellings and communal areas. The anthracite faceplate carries a Light Reflectance Value (LRV) of 8.9, providing sufficient visual contrast against typical wall finishes (most white walls measure LRV 75-85) to help visually impaired users locate the switch. The passive latching RCD resets automatically after a power cut, so circuits feeding essential appliances like fridges and freezers are not left isolated without manual intervention.

The unit requires a 35mm minimum back box depth and uses captive screw terminals that remain attached to the back plate during installation, reducing the risk of lost fixings. The thermoset resin construction is third-party tested to ISO 22196:2011 for anti-microbial properties, inhibiting bacterial growth on the surface in kitchens, bathrooms and clinical environments. The fused spur section accepts a standard 13A BS 1362 cartridge fuse (not included), allowing the load to be appropriately protected downstream of the RCD.

Specification
Height 86 mm
Width 86 mm
Projection 12 mm
Min. Mounting Box Depth 35mm
Construction Thermoset resin
Finish Anthracite
IP Rating IP20
Primary Voltage 230V 50Hz
Earth Terminal Yes
Terminal Captive
RCD functionality 30mA Type-A latching
Anti-Microbial Properties 3rd Party Tested to ISO 22196:2011
Warranty 2
Frequently Asked

What does Type A RCD protection cover?

Type A RCDs detect both standard AC earth leakage and pulsating DC residual currents up to 6mA. This makes them suitable for circuits feeding modern appliances with electronic controls, variable-speed drives, IT equipment, and LED lighting — all of which can introduce DC components that a standard AC-only RCD may not detect reliably.

Does the RCD need resetting after a power cut?

No. The passive latching design resets automatically when mains power is restored, so circuits feeding fridges, freezers and other essential appliances remain operational without manual intervention after an outage.

What fuse does the spur section take?

The fused spur accepts a standard 13A BS 1362 cartridge fuse (the same type used in UK plugs). The fuse is not included and must be selected based on the downstream load — typically 3A for lighting circuits, 5A for low-power appliances, or 13A for higher loads up to the maximum rating.

Is it suitable for bathroom installation?

The unit carries an IP20 rating, which is appropriate for indoor dry areas and zones outside the bathroom's direct spray/splash areas. It cannot be installed within zones 0, 1 or 2 of a bathroom as defined by BS 7671 wiring regulations. Consult a qualified electrician to confirm placement.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.