The Knightsbridge OP7E is a single-gang outdoor electrical enclosure rated IP66 and IK06, moulded from high-impact polycarbonate with a black body and a transparent smoked lid. The enclosure accepts standard Knightsbridge 7mm Curved Edge, Modular, or Grid accessories and provides multiple 20mm entry points for cable glands or conduit fittings.
Designed for outdoor switch and socket installations where weatherproofing is required, the enclosure mounts to brick, block, or timber via four fixing points on the back plate. The IP66 rating provides full protection against dust ingress and high-pressure water jets, while the IK06 rating certifies resistance to 1 joule mechanical impacts. The smoked lid allows visual inspection of switch positions or indicator lights without opening the enclosure.
The lid opens on a simple latch mechanism and can be propped open during wiring or maintenance, leaving both hands free. The internal cable channels are sized to accommodate thick over-moulded outdoor plugs without forcing or compression, and the 20mm entry points can be positioned on any face of the enclosure depending on conduit routing requirements. At 158.5mm high, 110.5mm wide, and 92.1mm projection from the mounting surface, the enclosure provides working depth for most outdoor accessories without excessive bulk on the wall.
Specification
| Height |
158.5mm |
| Width |
110.5mm |
| Projection |
92.1mm |
| Construction |
Polycarbonate |
| Finish |
Black |
| IP Rating |
IP66 |
Downloads
Product Specification Sheet
Frequently Asked
What accessories fit inside this enclosure?
The enclosure accepts Knightsbridge 7mm Curved Edge, Modular, and Grid accessories. Check that your chosen accessory is a single-gang width, as this is a 1-gang enclosure.
What does IP66 mean for outdoor use?
IP66 certifies full protection against dust and high-pressure water jets from any direction. The enclosure can be installed in locations exposed to rain, hose-washing, or coastal spray, provided the lid is properly closed and cable entries are sealed with appropriate glands.
Can the cable entries be positioned on any face?
Yes. Multiple 20mm entry points are provided on the enclosure body, allowing conduit or cable glands to be fitted on whichever face suits the installation routing. Unused entry points should remain sealed to maintain the IP66 rating.
What is the IK06 impact rating?
IK06 certifies resistance to 1 joule mechanical impacts, equivalent to a 500g mass dropped from 200mm. This provides protection against accidental knocks, tool drops, and light vandalism in outdoor and semi-public locations.