Adastra 1U 8 Gang UK PDU Rack Power Distribution - 1.8m Lead

£3199
The RRP is the manufacturer's recommended retail price of the item.
We are an Independent UK Company
Price match. Found it cheaper? Contact us
Trade Discount Available
Description

The Adastra 1U PDU is a rack-mounted power distribution unit with eight UK BS1363 sockets in a 483mm-wide 1U steel chassis, connected to mains via a 1.8m hardwired cable terminating in a UK plug. The unit provides distributed power access for equipment mounted in 19-inch racks without needing individual trailing sockets or extension leads cluttering the cabinet.

Designed for AV installation racks, broadcast studios, server rooms and network cabinets where multiple pieces of equipment need mains power from a single feed point. The 1U height occupies minimal vertical rack space and the eight sockets are arranged in a single horizontal row across the front panel, allowing most UK plugs to sit side-by-side without blocking adjacent sockets. The 13A total load capacity suits typical rack equipment draws including audio interfaces, routers, patch panels, small amplifiers and media players.

The steel chassis includes rack ears with standard 19-inch hole spacing for mounting in square-hole or tapped racks, and the 1.8m lead length provides routing flexibility when the PDU sits mid-rack but the main power inlet is at cabinet top or bottom. At 783g the unit adds minimal weight to a populated rack. No circuit protection is built into the PDU itself, so upstream MCB or RCD protection is required as part of the installation.

Specification
Dimensions 483mm x 53mm x 44mm
Lead length 1.8m
Length 1.8m
Current rating 10
Frequently Asked

What's the maximum load across all eight sockets?

The PDU is rated at 13A total load across all eight sockets combined, which equates to approximately 3,000W at 230V. Individual sockets do not have separate current limits, so the total draw from all connected equipment must stay below 13A to avoid tripping the upstream MCB.

Does the PDU include surge protection or circuit breakers?

No. The unit provides socket distribution only and contains no built-in MCB, RCD or surge protection. Upstream circuit protection is required as part of the rack installation, typically via the building's consumer unit or a dedicated distribution board feeding the cabinet.

Will all eight sockets accept plugs side-by-side?

Most standard UK plugs will sit side-by-side without obstruction. Larger wall-wart power supplies or right-angled plugs may block one adjacent socket depending on their physical size and plug orientation.

Can the 1.8m lead be replaced or extended?

The lead is hardwired into the PDU chassis and not user-replaceable. If the 1.8m length is insufficient, the PDU can be fed from an extension lead or the rack repositioned closer to the mains outlet. Permanent extension should be done by a qualified electrician using appropriate cable rating.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.

See it lit, in person

Lighting looks different in a real room. Come and see our range at our showrooms in Birmingham, Hong Kong and Dubai, or talk to our design team wherever you are.

Niori lighting showroom trailer video with closeups of alabaster lighting

Why Niori

Over 20 years lighting homes worldwide

We are a specialist lighting and mirror retailer with showrooms in Birmingham, Hong Kong and Dubai, shipping to customers around the world. Our own design team is here to help, from first idea to final fitting.

Genuine products

An authorised stockist

Every product arrives brand new with the full manufacturer warranty. Found it cheaper elsewhere? Ask us about a price match.

Installation

Fits standard UK back boxes

Designed to fit standard UK back boxes for a straightforward swap of your existing fittings.

Ordering with us

Free delivery over £99

Free delivery on orders over £99, in the UK and worldwide. Easy returns within 14 days, subject to our returns policy. Full manufacturer warranty included.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The Adastra 1U PDU is a rack-mounted power distribution unit with eight UK BS1363 sockets in a 483mm-wide 1U steel chassis, connected to mains via a 1.8m hardwired cable terminating in a UK plug. The unit provides distributed power access for equipment mounted in 19-inch racks without needing individual trailing sockets or extension leads cluttering the cabinet.

Designed for AV installation racks, broadcast studios, server rooms and network cabinets where multiple pieces of equipment need mains power from a single feed point. The 1U height occupies minimal vertical rack space and the eight sockets are arranged in a single horizontal row across the front panel, allowing most UK plugs to sit side-by-side without blocking adjacent sockets. The 13A total load capacity suits typical rack equipment draws including audio interfaces, routers, patch panels, small amplifiers and media players.

The steel chassis includes rack ears with standard 19-inch hole spacing for mounting in square-hole or tapped racks, and the 1.8m lead length provides routing flexibility when the PDU sits mid-rack but the main power inlet is at cabinet top or bottom. At 783g the unit adds minimal weight to a populated rack. No circuit protection is built into the PDU itself, so upstream MCB or RCD protection is required as part of the installation.

Specification
Dimensions 483mm x 53mm x 44mm
Lead length 1.8m
Length 1.8m
Current rating 10
Frequently Asked

What's the maximum load across all eight sockets?

The PDU is rated at 13A total load across all eight sockets combined, which equates to approximately 3,000W at 230V. Individual sockets do not have separate current limits, so the total draw from all connected equipment must stay below 13A to avoid tripping the upstream MCB.

Does the PDU include surge protection or circuit breakers?

No. The unit provides socket distribution only and contains no built-in MCB, RCD or surge protection. Upstream circuit protection is required as part of the rack installation, typically via the building's consumer unit or a dedicated distribution board feeding the cabinet.

Will all eight sockets accept plugs side-by-side?

Most standard UK plugs will sit side-by-side without obstruction. Larger wall-wart power supplies or right-angled plugs may block one adjacent socket depending on their physical size and plug orientation.

Can the 1.8m lead be replaced or extended?

The lead is hardwired into the PDU chassis and not user-replaceable. If the 1.8m length is insufficient, the PDU can be fed from an extension lead or the rack repositioned closer to the mains outlet. Permanent extension should be done by a qualified electrician using appropriate cable rating.

Shipping & Returns

Delivery UK delivery is £14.99, and delivery is free on all orders of £99 or more, in the UK and internationally.

Returns If you change your mind, you have 14 days from delivery to tell us, and a further 14 days to send the goods back. Return postage for a change-of-mind return is paid by you. Change-of-mind returns are subject to an inspection and handling deduction. See our full returns policy.

To arrange a return, call us on 020 8149 5199 or use our contact page.