Description
The Sangamo E855 is a programmable digital time switch in a 4-pin round pattern configuration, rated at 20A for switching immersion heaters, heating circuits, lighting banks and other timed loads. It offers 7-day programming with independent daily schedules, allowing up to 48 on and 48 off operations per day (96 total switching events), and includes automatic BST/GMT changeover for accurate timekeeping across clock changes.
Designed for residential immersion heater control, commercial lighting schedules, and industrial process timing, the E855 fits standard 4-pin round sockets in consumer units and distribution boards. The temporary override button allows manual switching without losing the stored programme, and the holiday mode suspends automatic operation when a property is unoccupied. The 20-day battery reserve maintains programme memory during mains interruptions.
The unit measures 104mm × 83mm × 134mm and weighs 380g, fitting within the space envelope of most consumer unit enclosures that accept 4-pin round-pattern timers. The digital interface replaces older mechanical segment timers, offering finer time resolution and independent day programming where mechanical alternatives use repeat patterns. The 20A rating handles resistive loads directly and can control larger loads via contactors.
Specification
| Product Net Weight (KG) |
0.38 |
| Product Gross Weight (KG) |
0.424 |
| Outer Gross Weight (KG) |
0.38 |
| Product Length (mm) |
104 |
| Product Width (mm) |
83 |
| Product Height (mm) |
134 |
| Outer Length (mm) |
104 |
| Outer Width (mm) |
83 |
| Outer Height (mm) |
134 |
Downloads
Product Specification Sheet
Product Manual
Frequently Asked
What loads can the E855 switch?
The 20A rating handles resistive loads up to 4,600W on 230V mains, covering most domestic immersion heaters, storage heaters and lighting circuits. For inductive or motor loads the effective rating is lower and may require a contactor for safe switching.
How is the programme retained during power cuts?
The 20-day battery reserve maintains the programme and clock during mains interruptions. The battery charges automatically when mains power is present and does not require user replacement under normal operating conditions.
Can each day have a different schedule?
Yes. Each of the seven days can be programmed independently with its own on and off times, allowing weekend and weekday schedules to differ. This contrasts with older mechanical timers which repeat the same pattern daily.
What is holiday mode?
Holiday mode suspends automatic switching while retaining the stored programme. The timer remains off until holiday mode is deactivated, preventing unnecessary heating or lighting operation when a property is unoccupied for extended periods.