The MagPro Addressable Repeater Panel is a wall-mounted remote display unit for ESP MagPro fire alarm control panels, providing fire alarm status monitoring at locations remote from the main control panel. The repeater displays fire, fault, system fault, delay, disable, test and power status indicators on a backlit LCD screen with dedicated LED indicators and navigation controls.

Designed for commercial and industrial buildings where fire alarm status needs to be visible at multiple points — such as reception desks, security stations, or building management offices — the repeater connects to MagPro control panels via a ring network topology using RS485 communication. The network supports up to 32 repeater panels at distances up to 1000m from the control panel to each repeater, with each panel requiring a separate MAGPRO-NIC network interface card.

The repeater is compatible with MagPro16 control panels running firmware version 2.8 or higher, and with MagPro96 panels. It requires an external 24VDC power supply drawing a maximum of 110mA under normal operation. The 10,000-event log stored within the repeater provides a local audit trail of alarm and fault events without needing to access the main control panel. The unit measures 200 x 330 x 48mm and is designed for surface mounting on internal walls in protected environments.

Specification
Product Net Weight (KG) 2.46
Product Gross Weight (KG) 2.66
Outer Gross Weight (KG) 21.3
Outer Length (mm) 370
Outer Width (mm) 500
Outer Height (mm) 230
Frequently Asked

What MagPro control panels is this repeater compatible with?

The repeater is compatible with MagPro16 control panels running firmware version 2.8 or higher, and with MagPro96 control panels. It will not work with earlier MagPro16 firmware versions or with other fire alarm control panel brands.

How many repeater panels can be connected to a single control panel?

Up to 32 repeater panels can be networked to a single MagPro control panel using a ring network topology. Each repeater requires a separate MAGPRO-NIC network interface card, and the maximum distance from the control panel to any repeater is 1000m.

Does the repeater require its own power supply?

Yes. The repeater requires an external 24VDC power supply capable of delivering at least 110mA. The power supply is not included and must be specified separately based on the installation requirements.

What information does the repeater display?

The repeater displays fire alarm status, general fault, system fault, delay, disable, test and power status on a backlit LCD screen with dedicated LED indicators. It also stores a 10,000-event log that can be accessed locally without needing to visit the main control panel.

Shipping & Returns

Free worldwide delivery

Free worldwide delivery on all orders over £99. International orders for third-party brand products may be subject to an additional courier surcharge based on volumetric weight, particularly on larger lighting fixtures — if a surcharge applies, our team will email you with the amount before dispatch and you can proceed or cancel for a full refund. See full delivery terms.

Returns

30-day returns window from delivery. As all our products are electrical or lighting goods, returned items must be inspected and recertified by a qualified electrician before resale — the cost of this inspection (25–40% of the item value) is deducted from your refund. Customers pay return shipping. Made-to-order, special-order and clearance items cannot be returned. See full returns policy.

Our Reviews

From first click to final installation, our customers share how Niori lights up their spaces. Read their words and envision what’s possible for yours.

Featured Projects

Step into our portfolio and see how we transform homes, restaurants, and commercial spaces and more, worldwide. Click here for a closer look at our latest projects.

Description

The MagPro Addressable Repeater Panel is a wall-mounted remote display unit for ESP MagPro fire alarm control panels, providing fire alarm status monitoring at locations remote from the main control panel. The repeater displays fire, fault, system fault, delay, disable, test and power status indicators on a backlit LCD screen with dedicated LED indicators and navigation controls.

Designed for commercial and industrial buildings where fire alarm status needs to be visible at multiple points — such as reception desks, security stations, or building management offices — the repeater connects to MagPro control panels via a ring network topology using RS485 communication. The network supports up to 32 repeater panels at distances up to 1000m from the control panel to each repeater, with each panel requiring a separate MAGPRO-NIC network interface card.

The repeater is compatible with MagPro16 control panels running firmware version 2.8 or higher, and with MagPro96 panels. It requires an external 24VDC power supply drawing a maximum of 110mA under normal operation. The 10,000-event log stored within the repeater provides a local audit trail of alarm and fault events without needing to access the main control panel. The unit measures 200 x 330 x 48mm and is designed for surface mounting on internal walls in protected environments.

Specification
Product Net Weight (KG) 2.46
Product Gross Weight (KG) 2.66
Outer Gross Weight (KG) 21.3
Outer Length (mm) 370
Outer Width (mm) 500
Outer Height (mm) 230
Frequently Asked

What MagPro control panels is this repeater compatible with?

The repeater is compatible with MagPro16 control panels running firmware version 2.8 or higher, and with MagPro96 control panels. It will not work with earlier MagPro16 firmware versions or with other fire alarm control panel brands.

How many repeater panels can be connected to a single control panel?

Up to 32 repeater panels can be networked to a single MagPro control panel using a ring network topology. Each repeater requires a separate MAGPRO-NIC network interface card, and the maximum distance from the control panel to any repeater is 1000m.

Does the repeater require its own power supply?

Yes. The repeater requires an external 24VDC power supply capable of delivering at least 110mA. The power supply is not included and must be specified separately based on the installation requirements.

What information does the repeater display?

The repeater displays fire alarm status, general fault, system fault, delay, disable, test and power status on a backlit LCD screen with dedicated LED indicators. It also stores a 10,000-event log that can be accessed locally without needing to visit the main control panel.

Shipping & Returns

Free worldwide delivery

Free worldwide delivery on all orders over £99. International orders for third-party brand products may be subject to an additional courier surcharge based on volumetric weight, particularly on larger lighting fixtures — if a surcharge applies, our team will email you with the amount before dispatch and you can proceed or cancel for a full refund. See full delivery terms.

Returns

30-day returns window from delivery. As all our products are electrical or lighting goods, returned items must be inspected and recertified by a qualified electrician before resale — the cost of this inspection (25–40% of the item value) is deducted from your refund. Customers pay return shipping. Made-to-order, special-order and clearance items cannot be returned. See full returns policy.