{"product_id":"sangamo-71111-1-module-1-channel-7-day-din-rail-time-switch-16a","title":"Sangamo 71111 1 Module 1 Channel 7 Day DIN Rail Time Switch - 16A","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Sangamo 71111 is a single-module 7-day DIN rail time switch with a 16A volt-free changeover contact and 46 memory locations for programmable switching events. The unit fits a standard 35mm DIN rail and occupies one module width (18mm), making it suitable for compact consumer units and distribution boards where panel space is limited. The LCD display shows current time, day, switching status and programmed events.\u003c\/p\u003e\n\u003cp\u003eDesigned for controlling lighting circuits, heating systems, ventilation equipment and other scheduled loads in commercial, industrial and domestic installations, the 71111 operates on 230V 50-60Hz mains with a 10-year battery reserve maintaining programmed settings during power outages. The volt-free changeover contact allows the switch to control circuits independent of the mains supply voltage, providing flexibility for low-voltage signalling or interfacing with other control systems.\u003c\/p\u003e\n\u003cp\u003eStandard programming is done via the four red buttons on the front panel, allowing up to 46 on\/off events to be set across the week. The unit is also compatible with Sangamo's optional key programming tool and EasyVUE Connect hub (sold separately), which enable remote programming and network control where multiple time switches need coordinated scheduling. The changeover contact provides both normally-open and normally-closed outputs from a single relay, giving choice between fail-safe-on or fail-safe-off behaviour depending on wiring configuration.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_71111_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_71111.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow many switching events can be programmed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 71111 stores up to 46 independent on\/off switching events across the 7-day week. Each event can be set to specific times on selected days, allowing complex scheduling patterns for different weekday and weekend requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does volt-free contact mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16A changeover contact is electrically isolated from the 230V mains supply that powers the time switch itself. This allows the contact to switch low-voltage circuits, DC systems, or any other voltage independent of the mains, making the switch suitable for signalling applications and interfacing with control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it retain settings during a power cut?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The internal battery provides a 10-year reserve that maintains all programmed events, time and date settings during mains power interruptions. The battery is not user-replaceable; the unit is typically replaced at end of battery life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat DIN rail does it fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 71111 clips onto standard 35mm DIN rail (TS35) used in most consumer units and distribution boards. It occupies one module width (18mm), equivalent to a single-pole MCB.\u003c\/p\u003e","brand":"Sangamo","offers":[{"title":"Default Title","offer_id":45294162215179,"sku":"71111","price":87.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/71111_4ac5aebd-39e0-410e-8211-a9633413b850.jpg?v=1714668957","url":"https:\/\/niori.co.uk\/products\/sangamo-71111-1-module-1-channel-7-day-din-rail-time-switch-16a","provider":"Niori","version":"1.0","type":"link"}