{"product_id":"sangamo-7-day-panel-timer-switch-16a-battery-backup","title":"Sangamo 7 Day Panel Timer Switch - 16A Battery Backup","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Sangamo FS 64.38 is a 7-day analogue panel timer with a voltage-free 16A changeover contact and a 100-hour battery backup. The timer uses a mechanical dial with captive 1-hour segments that are manually pushed in or pulled out to create the on\/off programme, running on a 24-hour clock face across seven days. The voltage-free contact allows the timer to control loads on circuits separate from the timer's own power supply, making it suitable for switching heating, pumps, lighting, ventilation and industrial equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for installation in control panels, distribution boards, or mounted directly to walls via the surface-mount option, the timer fits standard 35mm DIN rail or can be panel-mounted using the fixing lugs visible on the body. The 97mm x 80mm footprint and 62mm depth fit most enclosures designed for modular timers. The manual override button on the top of the unit allows the contact to be manually switched on or off with automatic return to the programmed schedule, useful for testing or temporary override without disrupting the weekly programme.\u003c\/p\u003e\n\u003cp\u003eThe 100-hour battery reserve maintains the clock and programme during power cuts or when the timer is disconnected for installation work, so the schedule does not need to be reprogrammed after brief outages. The contact status display shows whether the output is currently on or off. Made in Germany, the timer operates on 230V 50-60Hz mains supply and the contact is rated at 16A 250V, handling resistive loads up to 3,680W or inductive loads following the manufacturer's derating guidance in the manual.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_PA16921_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_PA16221-PA16922.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does voltage-free contact mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16A changeover contact is isolated from the timer's own power supply, allowing it to switch loads on circuits with different voltages or to control multiple independent circuits. This makes the timer safe for use in systems where the timer's 230V supply must not appear on the switched circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the weekly programme set?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe dial has captive 1-hour segments around a 24-hour clock face. Push a segment inward to switch the output on during that hour, pull it outward to switch the output off. The dial rotates through seven days, so you set Monday, Tuesday, Wednesday etc. in sequence as the dial turns.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens during a power cut?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 100-hour battery reserve keeps the clock running and preserves the programme for up to four days without mains power. When power returns, the timer continues from the correct time without needing to be reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted on DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The timer fits standard 35mm DIN rail using the clips on the rear of the body. It can also be panel-mounted using the fixing lugs or surface-mounted to a wall using the appropriate backplate.\u003c\/p\u003e","brand":"Sangamo","offers":[{"title":"Default Title","offer_id":45294152581387,"sku":"PA16921","price":56.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/PA16921_9b228957-9c03-43e6-aa13-a451b315e530.jpg?v=1714668753","url":"https:\/\/niori.co.uk\/products\/sangamo-7-day-panel-timer-switch-16a-battery-backup","provider":"Niori","version":"1.0","type":"link"}