{"product_id":"magpro-2-input-2-output-module-with-isolator-en54-18","title":"MagPro 2 Input 2 Output Module with Isolator - EN54-18","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe MagPro 2 Input 2 Output Module is an addressable fire alarm interface module with two monitored inputs, two relay outputs and a built-in loop isolator, certified to EN54-18. The module is loop-powered, drawing its operating current directly from the addressable fire detection loop rather than requiring a separate power supply.\u003c\/p\u003e\n\u003cp\u003eDesigned for commercial fire alarm systems where remote monitoring and control is needed, the module links fire panel inputs to external signalling devices, HVAC shutdown relays, door holders or monitoring station equipment. The two monitored inputs can accept contact closures from manual call points, beam detectors or third-party devices not directly addressable on the loop. The two outputs provide volt-free relay contacts that activate on command from the fire panel.\u003c\/p\u003e\n\u003cp\u003eThe built-in isolator protects the addressable loop from short-circuit faults downstream of the module. If a fault occurs on the wiring connected to the module, the isolator prevents the entire loop from failing, maintaining communication with other devices on the system. The module mounts in a standard IP40-rated enclosure with green terminal blocks for field wiring and programming via the fire panel's loop addressing tools.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_MAGPRO-2i2O_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_MAGPRO-2i2O.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the built-in isolator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe isolator protects the addressable loop from short-circuit faults on the wiring connected to the module. If a fault occurs downstream, the isolator prevents the entire loop from failing, maintaining communication with other devices on the fire alarm system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require separate power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module is loop-powered, drawing its operating current directly from the addressable fire detection loop. No additional power supply is needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat can the monitored inputs accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe two monitored inputs accept volt-free contact closures from devices like manual call points, beam detectors or third-party equipment that cannot be directly addressed on the loop. The panel monitors the state of these contacts and can trigger alarms or actions based on input changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the relay outputs rated for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe datasheet and manual linked in the Downloads section provide the exact volt-free relay contact ratings for the two outputs. Typical applications include activating external sounders, shutting down HVAC systems or signalling remote monitoring stations.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294157660427,"sku":"MAGPRO-2i2O","price":68.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/MAGPRO-2i2O_fe65157c-372c-4cfb-87d4-0d9e3c688f14.jpg?v=1714668876","url":"https:\/\/niori.co.uk\/products\/magpro-2-input-2-output-module-with-isolator-en54-18","provider":"Niori","version":"1.0","type":"link"}