{"product_id":"magfire-2-zone-conventional-fire-alarm-panel-metal-enclosure","title":"MAGfire 2 Zone Conventional Fire Alarm Panel - Metal Enclosure","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe MAGfire MAG2 is a 2-zone conventional fire alarm control panel housed in a white powder-coated metal enclosure with a front-mounted control interface. The panel supports up to 30 fire detectors per zone plus unlimited manual call points, giving a maximum system capacity of 60 automatic detectors across both zones. Zone configuration is programmable via the front panel controls, and active end-of-line monitoring detects circuit faults and detector head removal in real time.\u003c\/p\u003e\n\u003cp\u003eDesigned for small commercial and light industrial installations where two detection zones provide adequate coverage, the panel includes integral sounder output circuits with individual fault identification and zone-by-zone isolation capability. A one-man walk test mode allows a single engineer to test detector response without holding down a test button at the panel. The volt-free fire relay and volt-free fault relay provide remote signalling to building management systems or remote monitoring stations.\u003c\/p\u003e\n\u003cp\u003eThe panel is BS5839 and EN54 Part 2 and Part 4 compliant and carries CE certification. It operates from a single 12V standby battery (not included), reducing installation and maintenance complexity compared to dual-battery systems. The metal enclosure provides physical protection and earthing in industrial environments. A class change facility allows the system to be reconfigured between day and night operation modes, and the security key function prevents unauthorised changes to zone programming or system settings.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_MAG2_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_MAG2-4.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow many detectors can the panel support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MAG2 supports up to 30 fire detectors per zone, giving a maximum of 60 automatic detectors across the two zones. Manual call points can be added without limit to either zone. This capacity suits small commercial premises, light industrial units and multi-tenanted buildings where two detection zones provide adequate area coverage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat battery does the panel require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe panel operates from a single 12V standby battery, which is not included in the box. The battery compartment is sized for standard 12V 7Ah sealed lead-acid batteries commonly used in fire and security systems. Battery capacity should be calculated based on the total current draw of detectors, sounders and the panel itself during a mains failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the panel BS5839 compliant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The MAG2 is compliant with BS5839 (the UK code of practice for fire detection and alarm systems) and EN54 Part 2 and Part 4 (European fire alarm control and power supply standards). It carries CE certification and is suitable for installation in commercial and industrial premises under current UK fire safety regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the one-man walk test facility?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOne-man walk test mode allows a single engineer to test detector response without needing a second person to monitor the panel. When activated, the panel enters test mode and indicates detector activation via the control interface while suppressing full alarm output, allowing the engineer to walk the site and verify each detector responds correctly without triggering building evacuation.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294166475019,"sku":"MAG2","price":107.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/MAG2_89db3762-ee51-4919-89a5-40171578337d.jpg?v=1714669009","url":"https:\/\/niori.co.uk\/products\/magfire-2-zone-conventional-fire-alarm-panel-metal-enclosure","provider":"Niori","version":"1.0","type":"link"}