{"product_id":"magduo-2-zone-two-wire-fire-alarm-panel-kit-black","title":"MagDuo 2 Zone Two-Wire Fire Alarm Panel Kit - Black","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe MagDuo 2 Zone Fire Alarm Panel Kit combines an ESP MAGDUO2B two-zone, two-wire fire panel in a black metal enclosure with seven selectable optical smoke\/heat detectors, two resettable manual call points and a detector head removal tool. The two-wire architecture runs both power and signals on a single cable loop per zone, reducing installation time and cable costs compared to conventional four-wire systems.\u003c\/p\u003e\n\u003cp\u003eDesigned for small commercial premises, light industrial buildings, care homes and multi-occupancy residential buildings where a two-zone setup meets fire safety regulations, the kit provides all components needed for a basic addressable fire alarm installation except the two 12V 3.2Ah SLA standby batteries required by the panel. Six detectors include optical smoke\/heat sensing with integral sounders and bases, one detector adds a strobe for corridor or area-of-refuge installation, and the two call points allow manual triggering from exit routes.\u003c\/p\u003e\n\u003cp\u003eThe MAGDUO2B panel fits a 380 x 350 x 240mm black steel cabinet and accepts up to two detection zones, each loop capable of supporting multiple detectors and call points on a single two-core cable run. The optical detectors are field-selectable between smoke and heat modes via a switch on the detector head, allowing the system to be configured room-by-room without needing different detector models. The integral sounders in each detector provide distributed audio alarm coverage without requiring separate sounder circuits.\u003c\/p\u003e\n\u003cp\u003eThe kit supplies the panel, detectors, call points and removal tool but does not include the standby batteries (2 x 12V 3.2Ah SLA required), cabling between zones and devices, or any additional detectors or call points needed to meet site-specific fire risk assessments. Installation must be carried out by a competent fire alarm engineer in accordance with BS 5839-1 and local building regulations.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_MAGDUO2BKIT_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat batteries does the panel require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MAGDUO2B panel requires 2 x 12V 3.2Ah sealed lead-acid (SLA) batteries for standby power. These are not included in the kit and must be purchased separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the detectors be switched between smoke and heat modes after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each MAGDUOSHDS and MAGDUOSHDSS detector has a field-selectable switch on the head allowing it to operate as either an optical smoke detector or a heat detector, configurable room by room without changing hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many detectors can each zone support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MAGDUO2B two-wire panel supports up to two zones. The maximum number of devices per zone depends on cable run length and power draw — consult the ESP MagDuo technical manual or a qualified fire alarm installer for site-specific calculations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit meet UK fire alarm standards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe kit components are designed for use in systems installed to BS 5839-1. However, compliance depends on correct installation, configuration, testing and commissioning by a competent fire alarm engineer in accordance with the specific fire risk assessment for the building.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294238269707,"sku":"MAGDUO2BKIT","price":571.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/MAGDUO2BKIT_6f38d93d-8000-4d2d-bb86-e071be9d6d87.jpg?v=1714669896","url":"https:\/\/niori.co.uk\/products\/magduo-2-zone-two-wire-fire-alarm-panel-kit-black","provider":"Niori","version":"1.0","type":"link"}