{"product_id":"knightsbridge-torlan-6ft-30w-60w-cct-emergency-non-corrosive-batten-ip65-ik08-sensor","title":"Knightsbridge Torlan 6ft 30W\/60W CCT Emergency Non-Corrosive Batten IP65 IK08 - Sensor","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Knightsbridge Torlan is a 1828mm (6ft) non-corrosive batten fitting with switchable 30W or 60W LED output, selectable colour temperature (3000K, 4000K or 5700K), integrated 3-hour emergency backup and a fully adjustable microwave sensor. The polycarbonate housing carries an IP65 weatherproof rating and an IK08 impact rating, allowing installation in demanding indoor and outdoor environments including car parks, warehouses, loading bays, agricultural buildings and covered walkways.\u003c\/p\u003e\n\u003cp\u003eBoth wattage and colour temperature are adjusted via internal DIP switches before installation, giving specifiers flexibility to match the fitting to the exact requirements of each zone without stocking multiple SKU variants. At 30W the batten delivers 4,750 lumens at 4000K (158 lm\/W), and at 60W it delivers 8,660 lumens at 4000K (144 lm\/W). The integrated microwave sensor allows automatic switching in circulation areas, stores and car parks where occupancy-based control reduces running hours and energy consumption.\u003c\/p\u003e\n\u003cp\u003eThe emergency function provides 3-hour backup at 385 lumens using a maintenance-free LiFePO4 battery, with selectable maintained, non-maintained or switched modes to comply with BS 5266-1 emergency lighting regulations. The polycarbonate construction resists corrosion in damp and coastal environments, and the stainless steel diffuser clips provide secure fastening without plastic degradation over time. The 90mm square cross-section profile allows surface mounting to ceilings, walls and soffits, with optional suspension accessories available separately. The opal diffuser provides 150-degree beam spread, giving broad uniform coverage across loading areas, production floors and circulation routes.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e1828 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProjection\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e230V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffuser\u003c\/td\u003e\n\u003ctd\u003eOpal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency\u003c\/td\u003e\n\u003ctd\u003eMaintained \/ Non-maintained \/ Switched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Technology\u003c\/td\u003e\n\u003ctd\u003eSMD LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimmable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL70B50\u003c\/td\u003e\n\u003ctd\u003e60000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Rating (Class) post 2021 SLR\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Angle\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCT\u003c\/td\u003e\n\u003ctd\u003e3000\/4000\/5700 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Colour\u003c\/td\u003e\n\u003ctd\u003eCCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens\u003c\/td\u003e\n\u003ctd\u003e4300\/4750\/4560, 7475\/8660\/8040 lm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens (Light Source only)\u003c\/td\u003e\n\u003ctd\u003e10000 lm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens (Em. mode)\u003c\/td\u003e\n\u003ctd\u003e385 lm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWattage\u003c\/td\u003e\n\u003ctd\u003e30\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficacy\u003c\/td\u003e\n\u003ctd\u003e164.8 lm\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRI\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDriver Type\u003c\/td\u003e\n\u003ctd\u003eConstant Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Information\u003c\/td\u003e\n\u003ctd\u003e(excluding battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_5727894_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between 30W and 60W output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe wattage is selected via an internal DIP switch accessible when the diffuser is removed before installation. The switch setting determines whether the batten operates at 30W (4,750 lumens at 4000K) or 60W (8,660 lumens at 4000K). Once set, the wattage remains fixed until manually changed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between maintained, non-maintained and switched emergency modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn maintained mode the emergency lamp stays on continuously when mains power is present. In non-maintained mode the emergency lamp only activates during a mains failure. In switched mode the main fitting is controlled by a switch but the emergency lamp activates automatically during mains failure. The mode is selected via internal DIP switches before installation to comply with BS 5266-1 requirements for the specific application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the microwave sensor work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated microwave sensor detects movement within its coverage zone and switches the batten on automatically. Sensitivity and hold time are adjustable via controls accessible when the diffuser is removed. The sensor is useful in car parks, storage areas and circulation routes where occupancy-based control reduces energy consumption by switching off during unoccupied periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IP65 rating protects against water jets from any direction, making the batten suitable for covered outdoor areas including loading bays, external covered walkways, agricultural buildings and canopied car parks. The polycarbonate housing resists corrosion in damp and coastal environments, and the IK08 impact rating provides protection against mechanical impact.\u003c\/p\u003e","brand":"Knightsbridge","offers":[{"title":"Default Title","offer_id":45293687243019,"sku":"TORCWMEM6","price":84.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/1796252_475cc0b6-355c-405d-b96a-e1de2d60a830.jpg?v=1714662609","url":"https:\/\/niori.co.uk\/products\/knightsbridge-torlan-6ft-30w-60w-cct-emergency-non-corrosive-batten-ip65-ik08-sensor","provider":"Niori","version":"1.0","type":"link"}