{"product_id":"esp-magduo-2-wire-resettable-manual-fire-alarm-call-point-surface-mount","title":"ESP MagDuo 2-Wire Resettable Manual Fire Alarm Call Point - Surface Mount","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe ESP MagDuo is a 2-wire resettable manual fire alarm call point in a 120mm square red housing, designed for surface mounting in commercial fire alarm systems. The unit includes a built-in end-of-line function that allows it to monitor the circuit continuity without requiring separate EOL resistors, simplifying installation on 2-wire addressable or conventional fire alarm panels.\u003c\/p\u003e\n\u003cp\u003eDesigned for corridors, stairwells, exits and other escape routes where building occupants need to manually trigger the fire alarm, the call point sits at the standard 1.4m height above finished floor level. The resettable mechanism allows the call point to be reset using a key after activation, avoiding the need to replace frangible elements each time the alarm is tested or triggered. The red housing with white pictogram markings provides high visibility against most wall finishes.\u003c\/p\u003e\n\u003cp\u003eThe 120mm x 120mm footprint and 70mm projection from the wall allow the call point to be surface-mounted directly onto plasterboard, masonry or cavity walls without recessing. The IP21C rating provides protection against solid objects above 12.5mm diameter and vertically dripping water, making it suitable for indoor use in dry areas. The device base is supplied with the unit and includes the terminal connections for the 2-wire loop.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_MAGDUOCP_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_MAGDUOCP.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the built-in end-of-line function do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe built-in EOL function monitors the circuit continuity on the 2-wire loop without needing separate end-of-line resistors at the last device. This simplifies wiring on addressable and conventional fire alarm panels that use 2-wire topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the call point be reset after activation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The MagDuo uses a resettable mechanism that can be reset with a key after the alarm has been activated, avoiding the need to replace frangible glass or plastic elements each time the system is tested or triggered.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fire alarm panels is it compatible with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MagDuo is designed for 2-wire addressable or conventional fire alarm panels. Compatibility depends on the panel's protocol and voltage requirements — check the specification sheet or contact us to confirm compatibility with your specific panel model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat height should it be mounted at?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUK fire safety guidance recommends manual call points be mounted at 1.4m above finished floor level, measured to the centre of the faceplate. This height provides accessibility for most building occupants while avoiding accidental activation.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294104674571,"sku":"MAGDUOCP","price":21.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/MAGDUOCP_34105103-0032-498a-880b-9b2e38a65759.jpg?v=1714668145","url":"https:\/\/niori.co.uk\/products\/esp-magduo-2-wire-resettable-manual-fire-alarm-call-point-surface-mount","provider":"Niori","version":"1.0","type":"link"}