{"product_id":"esp-magduo-2-wire-resettable-fire-alarm-call-point-ip65","title":"ESP MagDuo 2-Wire Resettable Fire Alarm Call Point - IP65","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe ESP MagDuo is a resettable manual fire alarm call point with IP65 ingress protection, designed for surface-mount installation on conventional 2-wire fire alarm systems. The red polycarbonate housing measures 120mm square with a 70mm projection and contains a built-in end-of-line resistor, reducing wiring complexity on installation.\u003c\/p\u003e\n\u003cp\u003eDesigned for indoor and outdoor use where dust and water ingress is a concern, the IP65 rating protects the internal electronics from jet-wash cleaning, heavy rain and coastal spray. The call point suits commercial, industrial and marine environments including warehouses, loading bays, outdoor walkways, car parks and plant rooms. The 2-wire connection integrates with conventional fire alarm panels without needing separate alarm and monitoring circuits.\u003c\/p\u003e\n\u003cp\u003eThe resettable mechanism allows the call point to be reset after activation using a key (included with the device base), avoiding the need to replace consumable glass or plastic elements after every test or accidental activation. The white fascia displays the standard break-glass symbol in black, maintaining clear visibility in low-light conditions. The included device base allows the call point to be surface-mounted directly to masonry, rendered blockwork or weather-resistant backing boards without needing a separate back box.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_MAGDUOCPIP65_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_MAGDUOCPIP65.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does IP65 mean for this call point?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIP65 means the call point is protected against dust ingress (the \"6\") and low-pressure water jets from any direction (the \"5\"). It can withstand heavy rain, jet-washing and coastal spray, making it suitable for outdoor installation and industrial environments with regular washdown cleaning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the call point reset after activation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MagDuo uses a key-reset mechanism. After activation, insert the reset key (included with the device base) into the slot on the side of the housing and turn to reset the call point. This avoids the need to replace glass or plastic elements after testing or accidental activation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fire alarm systems is it compatible with?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MagDuo is designed for conventional 2-wire fire alarm systems. The built-in end-of-line resistor allows it to be wired as the final device on a circuit without needing a separate EOL module, simplifying installation on most conventional panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it include the mounting base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The device base is included and allows the call point to be surface-mounted directly to masonry, blockwork or weather-resistant boards without needing a separate back box. The cable entry is via knock-outs on the rear of the base.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294138327307,"sku":"MAGDUOCPIP65","price":39.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/MAGDUOCPIP65_8ec0d5c6-9235-49d8-bf04-a14f22d8fc16.jpg?v=1714668565","url":"https:\/\/niori.co.uk\/products\/esp-magduo-2-wire-resettable-fire-alarm-call-point-ip65","provider":"Niori","version":"1.0","type":"link"}