{"product_id":"duceri-led-emergency-exit-sign-bulkhead-ip65-white","title":"Duceri LED Emergency Exit Sign Bulkhead IP65 - White","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Duceri is a 3W LED emergency exit sign bulkhead with an IP65 rating, built around a white polycarbonate housing that measures 362mm wide by 117mm high. A lithium battery inside provides backup power during mains failure, keeping the green illuminated exit legend visible for the minimum statutory duration required by UK emergency lighting regulations. The unit can be configured as maintained (permanently lit) or non-maintained (illuminated only on mains failure) depending on the installation requirement.\u003c\/p\u003e\n\u003cp\u003eDesigned for commercial, industrial and public buildings where IP65 environmental protection is required, the Duceri suits car parks, loading bays, factory floors, outdoor covered walkways and wet areas such as commercial kitchens or washdown zones. The IP65 rating provides protection against dust ingress and low-pressure water jets from any direction, making the fitting suitable for regular washdown environments. The bulkhead mounts to wall or ceiling surfaces and the polycarbonate diffuser protects the LED array and legend panel from impact.\u003c\/p\u003e\n\u003cp\u003eThe Duceri includes multiple interchangeable legend inserts in the box, allowing the installer to select the appropriate directional arrow (left, right, up, down) or no-arrow running man pictogram required by the specific exit location. The white housing pairs neutrally with most commercial interiors and the green legend meets the international ISO 7010 standard for emergency exit signage. At 0.82kg net weight the fitting is light enough for single-person ceiling installation on standard fixing centres.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_D151AWH_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_D151AWHManual.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between maintained and non-maintained mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintained mode keeps the sign illuminated at all times, drawing from mains power. Non-maintained mode only illuminates the sign when mains power fails, running from the battery. The Duceri can be configured as either during installation depending on the specific requirements of the building and the local fire officer's preferences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does the battery last during a power cut?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe lithium battery provides backup illumination for a minimum of 3 hours during mains failure, which meets UK Building Regulations Approved Document B requirements for most commercial premises. Actual duration depends on the battery condition and ambient temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat legend options are included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Duceri ships with multiple interchangeable legend inserts showing the running man pictogram with directional arrows (left, right, up, down) and a no-arrow version. The installer selects the appropriate legend for the exit location and clips it into the front panel during fitting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IP65 rating makes the Duceri suitable for outdoor use under cover, such as covered walkways, external stairwells and loading bay canopies. It is not rated for full exposure to direct weather without overhead protection.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294124466443,"sku":"D151AWH","price":28.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/D151AWH_310d6054-76fd-4205-aa99-8f621f2abfe2.jpg?v=1714668370","url":"https:\/\/niori.co.uk\/products\/duceri-led-emergency-exit-sign-bulkhead-ip65-white","provider":"Niori","version":"1.0","type":"link"}