{"product_id":"beacon-evcs-touchscreen-master-station-512-line-capability","title":"Beacon EVCS Touchscreen Master Station - 512 Line Capability","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Beacon EVCS master station is a wall-mounted control panel for emergency voice communication systems, designed to coordinate up to 512 individual call lines across care homes, hospitals, assisted living facilities and other institutional settings. The 4.3\" full-colour touchscreen interface allows operators to view incoming calls, locate outstations, and manage multiple simultaneous alerts from a single centralised position.\u003c\/p\u003e\n\u003cp\u003eBuilt for environments where immediate two-way communication is required under BS5839-9:2021 and BS8300 standards, the master station integrates assist call systems, Type A outstations (emergency refuge points), and Type B outstations (disabled toilet alarms). The large handset supports full-duplex audio, meaning both parties can speak and listen simultaneously without needing to press-to-talk. System expansion requires a BMNETEX expander module for every 8 lines beyond the base configuration.\u003c\/p\u003e\n\u003cp\u003eThe control panel measures 400mm wide by 350mm high by 150mm deep and weighs 4.2kg net, requiring secure wall mounting on a solid substrate. Backup battery capability is built into the unit, though the battery itself is sold separately. The touchscreen displays caller location, call type and system status at a glance, reducing response time in critical situations. Cabling runs to outstations use standard Cat5e or Cat6 infrastructure, simplifying installation in retrofit scenarios where data cabling already exists.\u003c\/p\u003e\n\u003cp\u003eThe master station sits as the hub of a networked EVCS system rather than operating standalone. Incoming calls from outstations trigger visual and audible alerts on the touchscreen, allowing staff to prioritise and respond based on call type and location. The unit's compliance with BS8300 means it meets accessibility requirements for public buildings, while BS5839-9:2021 compliance ensures it satisfies fire safety guidance for voice alarm systems in complex premises.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Gross Weight (KG)\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length (mm)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width (mm)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height (mm)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Length (mm)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Width (mm)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Height (mm)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_BMNET_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/manual_BMNET-FullManual.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of outstations this master station can handle?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe master station supports up to 512 individual call lines. Each BMNETEX expander module adds capacity for 8 lines, so a full 512-line system requires 64 expander modules networked to the master station.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the backup battery come included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The master station has built-in circuitry to support a backup battery, but the battery itself is sold separately and must be specified based on the required standby duration for the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is required to connect outstations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system uses standard Cat5e or Cat6 data cabling to connect outstations to the master station and expander modules. This allows retrofit installations to use existing structured cabling infrastructure where available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compliant with UK accessibility and fire safety standards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The master station is fully compliant with BS5839-9:2021 for emergency voice communication systems and BS8300 for accessibility in public buildings. See the datasheet in the Downloads tab for certification details.\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":45294249312523,"sku":"BMNET","price":1629.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/BMNET_14d7dd08-8833-450d-a7bb-b9b491c883ac.jpg?v=1714670091","url":"https:\/\/niori.co.uk\/products\/beacon-evcs-touchscreen-master-station-512-line-capability","provider":"Niori","version":"1.0","type":"link"}