{"product_id":"20ax-dp-key-switch-module-marked-emg-ltg-test-black-nickel","title":"20AX DP Key Switch Module Marked EMG LTG TEST - Black Nickel","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eThe Knightsbridge 20AX DP key switch module is marked 'EMG LTG TEST' for emergency lighting testing and control. The module clips into the front of Knightsbridge grid mounting frames (sold separately) and uses a removable key to restrict access to the emergency lighting circuit. The 20AX double pole switching rating disconnects both live and neutral lines when in the off position.\u003c\/p\u003e\n\u003cp\u003eDesigned for commercial, institutional and industrial installations where emergency lighting requires controlled testing and maintenance access, the module is typically installed near building entrances, plant rooms or facilities management areas. The key-operated switch prevents accidental activation or tampering by untrained staff, while allowing authorised personnel to test emergency lighting circuits during routine safety checks. The module fits standard Knightsbridge grid frames from 1-module to 6-module widths.\u003c\/p\u003e\n\u003cp\u003eThe black nickel finish on the faceplate provides a darker metallic tone than polished chrome or brushed steel, pairing well with contemporary commercial interiors and darker wall colours. The ABS and steel construction gives the module durability under frequent switching cycles, while the IP20 rating suits standard dry indoor environments. The 25mm projection from the wall once fitted into a grid frame means the module sits slightly proud of the faceplate, making the key slot easily accessible.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e56.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e24.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProjection\u003c\/td\u003e\n\u003ctd\u003e2.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecessed Depth\u003c\/td\u003e\n\u003ctd\u003e17.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Mounting Box Depth\u003c\/td\u003e\n\u003ctd\u003e35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction 2\u003c\/td\u003e\n\u003ctd\u003e\u0026amp; steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e230V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/products_3905423_datasheet.pdf\" target=\"_blank\"\u003eProduct Specification Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eFrequently Asked\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat grid frame does this module fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module fits Knightsbridge grid mounting frames in widths from 1-module to 6-module. The frame is sold separately and mounts into a standard 35mm minimum back box. Once the frame is fixed, modules clip in from the front without tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the key removable when the switch is on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKey switch modules typically allow key removal in one position only (usually the off position) to prevent the key being left in the lock. Check the product specification sheet in the Downloads tab for the exact key-removal behaviour of this model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 20AX rating mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e20AX means the module is rated for up to 20 amps of resistive load at 230V (4,600W), suitable for controlling emergency lighting circuits and other high-draw loads. The double pole (DP) rating means both live and neutral are switched, providing greater isolation than single-pole switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IP20 rating means the module is not protected against moisture ingress and is suitable only for dry indoor environments.\u003c\/p\u003e","brand":"Knightsbridge","offers":[{"title":"Default Title","offer_id":45293554073867,"sku":"GDM008BN","price":5.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/8993\/3835\/files\/459900_870af834-65e6-441c-8666-318e04190069.jpg?v=1714660262","url":"https:\/\/niori.co.uk\/products\/20ax-dp-key-switch-module-marked-emg-ltg-test-black-nickel","provider":"Niori","version":"1.0","type":"link"}